Chamber Without Multi-Tech Air Purifier |
Chamber With Multi-Tech Air Purifier |
ppmv: parts per million by
volume concentration ** Measurements taken throughout the
entire chamber.
Time |
ppmv |
12:45 |
0.0 |
13:00 |
5.8 |
13:15 |
5.8 |
13:30 |
5.8 |
13:45 |
5.8 |
14:00 |
5.8 |
14:15 |
5.8 |
14:30 |
5.8 |
14:45 |
5.8 |
15:00 |
5.8 | |
ppmv: parts per million by
volume concentration ** Measurements taken throughout the
entire chamber, and not just at the point where the air enters
the air purifier.
Time |
ppmv |
12:45 |
0.00 |
13:00 |
4.00 |
13:15 |
3.50 |
13:30 |
2.10 |
13:45 |
2.00 |
14:00 |
1.43 |
14:15 |
1.00 |
14:30 |
0.80 |
14:45 |
0.56 |
15:00 |
0.41 | |
Hydrogen Sulfide Test Details
Result: 93% of Hydrogen Sulfide
Removed
Chamber Size: 128 cubic feet (4' x 4' x
8')
Temperature: 75-80oF
Humidity:
50-60%
Performed by independent testing lab.
Test Description:
Hydrogen Sulfide was pumped into the air-tight
chamber in equal concentrations in both tests (Test A without the
Multi-Tech air purifier, and Test B with the Multi-Tech in operation
in the chamber). In Test A, a 5.8 ppmv concentration was maintained
for over 2 hours. With the same amount of H2S pumped into
the chamber in Test B (with the Multi-Tech air purifier in
operation) the concentration was brought down to 0.41 ppmv over the
same period of time, a 93% reduction. Unlike most air purifier
reduction rates, the measurements in this test were taken throughout
the chamber, outside the Multi-Tech air purifier, making these
results even more impressive. In other words, these test results are
an indication of how effectively the Multi-Tech will remove noxious
chemicals throughout the room, and not just from the air that passes
through the unit.
About Hydrogen Sulfide:
Hydrogen Sulfide (H2S), a strong gas
created by stagnant sewage, is one of the very worst, and most
difficult-to-remove pollutants known to man. An air purifier's
ability to remove H2S is a good indication of its ability
to remove strong odors and volatile organic chemicals
(VOCs).
99.5% Removal Rate of Particles in Chamber -
Smoke Particle Levels in Chamber WITHOUT the
Multi-Tech Air Purifier |
** Measurements taken
throughout the entire chamber. ** Smoke particles are a
good representation of particles in general, including
allergens.
|
Smoke Particles in Chamber
WITH the Multi-Tech Air Purifier |
** Measurements taken
throughout the entire chamber, and not just at the point where
the air enters the air purifier. ** Smoke particles are a
good representation of particles in general, including
allergens.
|
Smoke Particle Test
Details |
Overall Result:
99.5% of Smoke Particles Removed Chamber Size:
128 cubic feet (4' x 4' x 8') Temperature:
75-80oF Humidity: 50-60% Performed
by independent testing lab.
Test Description:
Smoke particles of various microscopic sizes
were pumped into the air-tight chamber in equal concentrations
in both tests (Test A without the Multi-Tech air purifier, and
Test B with the Multi-Tech in operation in the chamber). In
Test A, without the air purifier, the particle levels did not
decrease over the course of 7+ hours. With the same amount of
smoke particles pumped into the chamber in Test B (with the
Multi-Tech air purifier in operation) the concentration was
brought down by more than 99.5% over the same period of time.
Unlike the reduction rates quoted by most air purifiers, the
measurements in this test were taken throughout the chamber,
outside the Multi-Tech air purifier, making these results even
more impressive. In other words, these test results are an
indication of how effectively the Multi-Tech will remove
airborne particulate throughout the room, and not just from
the air that passes through the
unit. |